Besides, I use the Oracle Express for the db of DCNM since very 7.2. The performance is better than the POSTGRESQL.
You can follow the Oracle link below to have some basic knowledge of Oracle Express.
If you use SolarWind as your TFTP server, make sure .NetFramework 3.5 is required. See link below on how to enable it in Windows 2016 server.
After new DCNM server is in production, I plan for the firmware update on all the FC switches in the fabric. However, I find out both of the MDS9710 are affected by Cisco bug ID CSCvf99665
It show an invalid IPV6 IP address in the mgmt/0 interface and has a zero
length subnet mask.
Example:
::148.237.143.255/0Example:
Suggestion from support
(1)Open
a case and get Cisco TAC to send you a DPLUG file that will be downloaded and
run on the switch. We would run the DPLUG, do a 'copy r s' to save the configuration, then do a
'system switchover' and run 'copy r s' again.
(2)Upgrade to 8.1(1a). After the upgrade has completed, do a 'copy r s', do a 'system switchover' and after both supervisors are back up, then do another 'copy r s'.
(2)Upgrade to 8.1(1a). After the upgrade has completed, do a 'copy r s', do a 'system switchover' and after both supervisors are back up, then do another 'copy r s'.
On the safe side, we choose the 1st option and have support apply the DPLUG file. Everything is fine. Then, we update the firmware to 8.1(1a).